0086-510-85187837 24/7 Helpline
author:cc 2019-12-10
EBICO is based in Italy and the burner business is one of our strengths.We have formed strategic cooperation with Novar Bergamo and Vizcaya groups with strong burner development capabilities internationally.Optimize and integrate the today's combustion technological know-how assets in Europe to form EBICO's cutting-edge strategic system.With strategic partners or factories in Italy, Germany, Switzerland, the Netherlands and China, we have many years of ride in the design, development, advertising offerings and aid optimization of giant burners, fuel provide structures and automated manage systems.Our lookup focuses on large industrial burners, non-standard burners and some enormously refined combustion equipment.
EBICO provides wellknown and non-standard burners.The scientific utility of advanced separation science determines that it can adapt to very harsh environment, EBCIO burner entirely meets the necessities of boiler, energy plant, industrial boiler, warmth conduction oil furnace, asphalt mixing building drying cylinder and asphalt warmth conduction oil furnace.Advanced and unique graph thought has won the EBICO burner many markets, such as: low nitrogen emission popular burner and smart control which meet European CLASS I, CALSS II and CALSS III requirements in advance.EBICO burner presents customers with the most dependable products and services, while achieving a range of gas efficient and affordable configuration.At present, there are many burners for boilers, power plants, industrial boilers, thermal oil boilers, garbage incineration, asphalt mixing constructing heating services.
EBICO burner has a crew of notably technical experts who are in a position to analyze client requirements and talk about the satisfactory diagram and manufacturing structures with the consumer to thoroughly meet the specific necessities and expectations of the user.The most vital factor is to furnish speedy support service for customers.
The preference of EBICO burner capability that we have skilled companions with the equal desires in the identical industry, which permits the users to allocate economic and production sources to the maximum extent underneath the premise of entirely thinking about the ecological and environmental issues.
We can supply all sorts of burners with strength range of 85kw-86000kw.Specific are: traditional gas burner, non-standard custom burner, low nitrogen burner, pulverized coal burner, multi-fuel burner, low calorific cost burner.
Pressure conversion
1 bar is 10^5 Pa.
1 dyn/cm2 =0.1 Pa
Torr =133.322 Pa
1 mmHg (mmHg) =133.322 Pa
1 mm water column (mmH2O) =9.80665 Pa
Engineering atmospheric stress =98.0665 kPa
KPa =0.145 psi =0.0102 kg force/square centimeter (KGF /c㎡) =0.0098 atmospheric pressure (ATM)
1 psi =6.895 kPa =0.0703 kPa =0.0689 bar =0.068 atmosphere
1 bodily atmospheric pressure (ATM) =101.325 kPa =14.696 psi =1.0333 bar 1m³(gaseous) liquefied gasoline =2.3kg (liquid) liquefied gas
The proportion of common
0.81 kg/m&sup three gas;2.08 kg/m&sup three liquefied petroleum gas;City fuel 0.58kg/m³Air is 1.24 kg/m&sup 3;
Common volume: 1 gallon (gal) =3.785 liters (1)
Conversion of warmness transfer coefficient
Hour (kcal/ SQM. H) =1.16279 watts/SQM (w/ SQM)
1 kcal/(m.. ℃) [1 kcal/(m.h. ℃)) = 1.16279 w/(m. Kelvin) w/(m2. K)
1 British thermal unit /(ft. 2. H.℉) [Btu/(ft2.h.℉)] =5.67826 w/ (m. Kelvin) [(w/ m2.k)]
1 m2 h.℃/kcal (m2.h.℃/kcal) =0.86000 m2. Kelvin/watt (m2.k /W)
1 kcal (m.. ℃) (kcal/(m.h. ℃)) = 1.16279 W/(m. Kelvin) W/(m.K)
1 btu/(feet.. ℉) But/(ft. H. ℉) = 1.7303 W/(m. Kelvin) W/(m.K)
In addition to the installation of the fan in accordance with the relevant standards and in accordance with the graph drawing requirements for construction.The fan shall be installed in a role to ensure regular operation and convenient renovation of the required controls.
During installation, it is advocated that the fan and the air duct adopt gentle connection (flexible fabric and non-combustion), the length must no longer be less than 200mm, and the pipe diameter have to be the same as the inlet and outlet size of the fan.In order to make sure that the tender connection does now not show up distortion in the method of machine debugging, the installation should be fairly tight.The pipe diameter of the smoke and air duct at the outlet of the fan can solely be enlarged, not reduced.Pay attention to the route of airflow if there is a guide plate in soft connection.
A gentle connection is also cautioned between the inlet of the burner and the air duct, and the air duct between the blower and the burner should maintain a sure Angle.Vertical association is not effortless to purpose uneven combustion and vibration.Fan into the tuyere are generally adjustable door, the set up of inlet damper must pay interest to whether or not the path of information drift formed by using the blade Angle when opened is steady with the impeller rotation direction.
Fuel greater sensible manage system, adopt global famous manufacturer PLC as the core controller, in accordance to distinct fuels, the preference of exceptional manage procedures, to recognise the computerized ignition, automated flame-out protection system, computerized adjustment, computerized wind load and coal proportion adjustment of oil and gas, combustion fault computerized monitoring alarm, can implement chain and gear protection, at the equal time, the manage gadget can also be used with gear integration for an natural whole, to understand automatic tools operation parameters setting and burner operation parameters matching, enhance overall equipment automated manage effect.
Enough about how to clear up the hassle of burner
New electricity companies are now not only the direct beneficiaries of clean power consumption, however also essential participants, bearing important responsibilities.Participate in the spot strength market and auxiliary carrier market, enhance the machine dispatching potential in a market-oriented way, and promote the consumption of clean energy.