Research and explore a variety of energy joint scheduling.To study the joint optimization operation of thermal power and renewable energy on a pilot basis, and explore the formation of a joint dispatching unit for renewable energy power stations and thermal power plants.The joint dispatching unit is regarded as participating in the power market as a whole and accepting the instructions of the grid dispatching agency.In areas where hydropower is the main source of wind power and photovoltaic power, and in areas where wind power and photovoltaic power are developed simultaneously, pilot joint dispatching units that prevent coordinated operation of multiple power sources by region can be explored.We will encourage new nuclear power projects to build peak-regulating power supplies, such as pumped storage, in combination with local conditions.3VwBoiler Burner

Pressure conversion3VwBoiler Burner

1 bar is 10^5 Pa.3VwBoiler Burner

1 dyn/cm2 =0.1 Pa3VwBoiler Burner

Torr =133.322 Pa3VwBoiler Burner

1 mmHg (mmHg) =133.322 Pa3VwBoiler Burner

1 mm water column (mmH2O) =9.80665 Pa3VwBoiler Burner

Engineering atmospheric pressure =98.0665 kPa3VwBoiler Burner

KPa =0.145 psi =0.0102 kg force/square centimeter (KGF /c㎡) =0.0098 atmospheric pressure (ATM)3VwBoiler Burner

1 psi =6.895 kPa =0.0703 kPa =0.0689 bar =0.068 atmosphere3VwBoiler Burner

1 physical atmospheric pressure (ATM) =101.325 kPa =14.696 psi =1.0333 bar 1m³(gaseous) liquefied gas =2.3kg (liquid) liquefied gas3VwBoiler Burner

The proportion of common3VwBoiler Burner

0.81 kg/m&sup 3 gas;2.08 kg/m&sup 3 liquefied petroleum gas;City gas 0.58kg/m³Air is 1.24 kg/m&sup 3;3VwBoiler Burner

Common volume: 1 gallon (gal) =3.785 liters (1)3VwBoiler Burner

Conversion of heat transfer coefficient3VwBoiler Burner

Hour (kcal/ SQM. H) =1.16279 watts/SQM (w/ SQM)3VwBoiler Burner

1 kcal/(m.. ℃) [1 kcal/(m.h. ℃)) = 1.16279 w/(m. Kelvin) w/(m2. K)3VwBoiler Burner

1 British thermal unit /(ft. 2. H.℉) [Btu/(ft2.h.℉)] =5.67826 w/ (m. Kelvin) [(w/ m2.k)]3VwBoiler Burner

1 m2 h.℃/kcal (m2.h.℃/kcal) =0.86000 m2. Kelvin/watt (m2.k /W)3VwBoiler Burner

1 kcal (m.. ℃) (kcal/(m.h. ℃)) = 1.16279 W/(m. Kelvin) W/(m.K)3VwBoiler Burner

1 btu/(feet.. ℉) But/(ft. H. ℉) = 1.7303 W/(m. Kelvin) W/(m.K)3VwBoiler Burner

 3VwBoiler Burner

 3VwBoiler Burner

Product features3VwBoiler Burner

 3VwBoiler Burner

   Large adjustment ratio: 1:10, advanced electronic computing proportional mode, steady start up, high temperature control accuracy.3VwBoiler Burner

 3VwBoiler Burner

   The machine comes with integral compact structure; for the convenience of installation and maintenance, mobile wheel hub device is used3VwBoiler Burner

   integrally; oil (gas) supply line and control circuit are arranged compactly and ensures systematic connection; it is novel in design and good-3VwBoiler Burner

   looking.3VwBoiler Burner

 3VwBoiler Burner

   The fuel oil burner supplies oil at low pressure, air (steam) atomizing and can use poor oil.3VwBoiler Burner

 3VwBoiler Burner

   Fuel and combustion oxygen are computed and supplied separately, and the ratio is computed respectively by PLC, so as to ensure complete3VwBoiler Burner

   combustion and increase efficiency by 2%.3VwBoiler Burner

 3VwBoiler Burner

   The fan applies frequency converting control, so its annual power consumption reduces 30%-40%; featured in high anti-pressure capacity and  3VwBoiler Burner

   strong adaptation, it can control flame easily.3VwBoiler Burner

 3VwBoiler Burner

   The gas burner applies gas ring atomizing and ensures low NOx emission.3VwBoiler Burner

 3VwBoiler Burner

   Its safety, energy-saving and environmental protection performance meet European standards.3VwBoiler Burner

 3VwBoiler Burner

   Its elements are protected by protective measures, level of protection: IP55; that of master device reaches IP56-IP67. It improves safety and3VwBoiler Burner

   eliminates potential failure.3VwBoiler Burner

 3VwBoiler Burner

   Applicable fuel: gas, light oil, oil mixture, heavy/residual oil, pulverized coal, oil/gas dual purpose, oil/gas/coal multipurpose, etc.3VwBoiler Burner

 3VwBoiler Burner

   This series of burner is applicable for model 500-6000 asphalt mixing plant.3VwBoiler Burner

 3VwBoiler Burner

Quiet3VwBoiler Burner

The newly developed backflow hood type muffler and S-shaped air supply system have greatly decreased the noise level during burner operation. By replacing the traditional external muffler, it is able to offer a quiet environment.3VwBoiler Burner

 3VwBoiler Burner

 3VwBoiler Burner

Enough about how to solve the trouble of burner3VwBoiler Burner

For every customer, we are wholeheartedly service.Good quality and good service, this is the quality of EBICO, as a global enterprise, EBICO has always maintained strategic partnership with the world's top brand companies, this is one of our advantages, but also our sales network and service quality can continue to healthy development of important factors!Our sales network can radiate the world, thanks to our quality assurance.Our products have been verified by various countries and users, and our sales and service outlets are all over the world.EBICO's high quality products and perfect sales and service network are like a bridge of friendship, connecting customers with us.3VwBoiler Burner