Of combustion engine trouble eliminate methodological introduction
author:fly boy
2020-06-08
Below ignition breakdown normal condition, start burner 3 times continuously, did not ignite combustion to should be judged for ignition breakdown, need undertakes be checkinged accordingly will remove trouble. (Travel of accident of the wind when ignition is normal, the procedure is correct)</p><p><br/></p><p>Ignition breakdown</p><p><br/></p><p>Below normal condition, start burner 3 times continuously, did not ignite combustion to should be judged for ignition breakdown, need undertakes be checkinged accordingly will remove trouble. (Travel of accident of the wind when ignition is normal, the procedure is correct)</p><p><br/></p><p>Whether does the pressure of natural gas of examination of breakdown of 1 gas source maintain normally in 3-5kpa, exorbitant or too low all can appear the dot does not catch fire phenomenon. Processing technique; adjusts natural gas pressure regulator valve, have pressure set. </p><p><br/></p><p>Breakdown of 2 air door checks air door size, air door is in slant big when appear easily for many times the phenomenon that ignition does not wear, processing technique; moves air door appropriately small, but can not shut completely. </p><p><br/></p><p>Igneous electrode or ignition transformer breakdown ignited at 3 o'clock transformer not strike a light, or ignition electrode is too dirty when the place is wrong, all can appear ignition breakdown. Test of processing technique; ignites whether transformer ignites, clear ignition electrode, adjust ignition clearance to maintain 2-3mm. </p><p><br/></p><p>Group of a powerful person when breakdown of group of 4 a powerful person burning gas ignites normally will be seasonable ground open, can hear the voice of open, blaze won't be built when cannot be being opened, processing technique; checks coil of group of a powerful person, the open of control valve is spent. </p><p><br/></p><p>Igneous controller breakdown is all at 5 o'clock ignition program is given out by controller, controller attaint, cannot ignite normally. Processing technique; changes controller. </p><p><br/></p><p>When flameout breakdown burner runs combustion normally, abrupt put out a fire, for flameout breakdown. </p><p><br/></p><p>1 gas source is flabby after causing blaze to fluctuate, put out a fire, processing technique; adjusts pressure, start afresh. </p><p><br/></p><p>The blaze when breakdown of 2 blaze detector moves detects bougie ground connection, or too dirty when the blaze with be not measured normal, occurrence flameout. Processing technique; adjusts bougie position, clear bougie surface. Start afresh. </p><p><br/></p><p>Power source of 3 circuit breakdown flabby or be short of, cause the flameout in the process. Processing technique; contacts electrician to check power source and wiring. </p><p><br/></p><p>Burner does not start breakdown to press the pushbutton that start is long burner is not started</p><p><br/></p><p>1 outside receives temperature outside chain breakdown or pressure control did not arrive at; of the floor level that start to examine temperature or pressure set cost. </p><p><br/></p><p>Chain of 2 burner interior was not passed when exorbitant or atmospheric pressure is too low, wind pressure switch often is shut when closing, when air door orgnaization did not reach the designated position, all can appear, undertake checking stage by stage. </p><p><br/></p><p>Breakdown of 3 program controller did not undertake restoration, undertake restoration afresh. </p><p><br/></p><p>4, protection of overheat of fan electric machinery, undertake restoration to heating up relay. </p><p><br/></p><p>5, examination control ark starts pushbutton, normal. </p><p><br/></p><p>6, it is normal that examination of circuit breakdown circuit measures actuating signal, voltage insurance is normal. </p><p style="text-align: center;"><img src="http://www.shhtrn.com/Content/File_Img/S_Product/small/2018-12-29/201812291001003632039.png" /></p></div>HLMBoiler Burner