0086-510-85187837 24/7 Helpline
author: 2019-12-02
Basic knowledge of combustion engine maintenance
Basic knowledge of burner maintenance:
1. Keep boiler furnace clean and ensure air circulation in boiler room.When disassembling the burner, the inspection switch should be cut off first.
2. When the door is locked tightly, the door shall be unshaken and secure;
3. It is prohibited to burn paper and garbage with the boiler without special declaration;
4. The gas inlet pressure shall not exceed the maximum allowable pressure of the valve set indicated on the burner nameplate;
5. Keep the surroundings of the burner clean, so as not to absorb debris into the burner.
When the combustion engine is started, it must be guaranteed that:
1. The check switch is on, check the continuous phase;
2. The valves on the air supply pipeline and the heating system pipeline are open;
3. The gas pressure is within the pressure range required by the burner;
4. The regulating plate in the boiler flue must be open (if installed);
If the burner does not start:
1. Check whether the valve on the air supply pipe has been opened;
2. Close the start button and check the setting position of the thermostat, but do not adjust the inside of the thermostat;Check if the fuse is blown.
Combustion engine does not burn after ignition:
1. Master the starting condition of the combustion engine, but it is absolutely not allowed to start the combustion engine forcibly;
2. Do not reignite the burner before the residual gas in the boiler is exhausted;
3. If the burner has been unable to ignite, professional personnel should be asked to solve.
During the shutdown of the burner in summer:
1. Cut off the main inspection and the valve on the natural gas pipeline, if the combustion engine should be repaired in a short time.
2. Note that the newly installed chimney must be checked whether it is firm when the burner is working, and no vibration or other abnormalities shall occur;
3. Whether the newly used ignition device can ignite the gas;
4. If the ignition failure of the combustion engine requires restart, it must wait for about 10 minutes or so, until the residual gas in the furnace dissipates before restart the combustion.Multiple ignition is strictly prohibited.
5. When the boiler is started and ignited, it is strictly prohibited for all personnel to stay in the front and back of the boiler.
A burner is a thermal energy device that converts chemical energy into heat energy and controls and regulates the process of fuel combustion and conversion.The earliest burners in use in the world date back to the middle of the 19th century, when gas was used as an industrial fuel.In the mid-19th century, people reacted air or steam with coal, coke or charcoal at high temperature to make an artificial gas with low calorific value. This artificial gas was mainly made of carbon monoxide and hydrogen, while others, such as carbon dioxide and nitrogen, were very high in content.
EBICO provides light and heavy oil pump sets with filters, pumps and heaters (heavy oil). Filters and pumps are designed with one or both.Double circuit system is adopted to ensure that the system does not need to stop working in case of daily maintenance or failure.Heavy oil can be heated by electricity, heat conduction oil and steam medium to reach the viscosity required by physicochemical.
EBICO provides safe light and heavy oil models with matching valve sets, fuel quick automatic shutoff valves for burners, atomizing medium quick automatic shutoff valves, tubing and oil gun purge quick automatic shutoff valves.Pressure controller, pressure gauge and temperature gauge (heavy oil only). Modular design makes installation quick and easy.
Integrated control system is that we proposed earlier today's more advanced control mode, is widely used in Europe and the us some dimensions industry in our country and demanding enterprises choose this control concept, its core idea is to put the boiler and burner control together unified programming, making accurate digital control, this control model to avoid the original control of shortcomings, such as: scattered, incompatible, multipoint multiple handling, economic problems.
Its advantages are obvious:
Software compatibility optimization, electronic control uniformity, greatly improve the control accuracy, energy saving
Design and manufacture consistency, safety and reliability and production cost savings
Single human-computer interface dialogue
Operating system intuition
Improve maneuverability and safety
Single professional debugging, to ensure safety and efficiency
Continuity of one-stop after-sales service, greatly improve the work efficiency, reduce the service cost for users
One-click accessories, software and supply upgrades are guaranteed
After decades of development, EBICO is beginning to enter a critical period of second entrepreneurship.In the face of the changing market, tide business sea, only firm faith, never give up, forge ahead, constantly beyond, can stand the tide.In the future, we will continue to adhere to the safety, energy saving and environmental protection features of EBICO burner, and build EBICO into a value-added brand that leads the market, exceeds the budget and contributes to the society.
Contact information:
Contact number :0086-510-85169858
Website: www.ebico.com
Company address: no. 58, building 48, henghua science and technology park, xiuxi road, binhu district, jiangsu province