What should use boiler burner notice! _ exceeds opportunity of low nitrogen combustion

author: 2020-06-18

  What should use boiler burner notice! The air pollution of increasingly severe exacting discharges the country standard, thick as hail environmental protection policy, countrywide each district started boiler “ coal to correct the action of gas ” , wash out the coal fired boiler with serious pollution, convert we come to the gas fired boiler of clean environmental protection today introduce to use boiler burner to want what to notice
  What should use boiler burner notice!
1, air door size should match with nozzle norms photograph. When combustion machine is used, boiler of try out of the attune when because distribute boiler and combustion machine,leaving factory is abhorrent, so general need adjusts air door appropriately, still need to change sometimes what appropriate norms and gush angle of fire spend is oily.
  
2, oil absorption canal does not get bottom of gasoline tank of press close to, should maintain 80- - the distance of 120mm. To gasoline tank combustion engine should be shut before oiling, fuel course filters rear can infuse gasoline tank, oiling just can switch on the mobile phone afresh after 20 minutes. Oil path system must not leak oil and flat. Fuel of gasoline tank of the examination before machine of the combustion that start is enough.
  
3, detector of canister of combustion of burner of regular examination boiler, impeller, blaze and ignition electrode, clear degrease and carbon deposit. Especially blaze detector should keep clean more, must not touch water.
  
4, before igniting, need those who have period of time to air beforehand, blow the more than air in the chamber of a stove or furnace and flue divide or attenuant. Because inevitable ground is superabundant inside the chamber of a stove or furnace of combustion engine work,stay burn gas, if did not undertake air beforehand and igniting, have the risk that produces explosion. Need blows more than air be divided clean or attenuant, make sure chroma burning gas is not inside explosion limit. Air time and structure of the chamber of a stove or furnace and blowy quantity concern general setting to be 15-60 second beforehand.
  
5, if often be shut,a powerful person of electromagnetism of control burning gas needs model, once cut off the power, shut automatically cut off supply burning gas. Electromagnetism a powerful person is shut answer time ≤5s.