0086-510-85187837 24/7 Helpline
author:Martin 2019-10-22
Many projects to increase the flue gas external circulation, according to the on-site reaction, the flue gas recirculated condensed water is a lot, in winter, the wind duct will even freeze.This is because the hot and humid smoke and combustion fresh air mixed, mixed steam beyond the mixed air temperature of the saturated humidity, the excess steam formed condensed water.CO2 in the flue gas will dissolve in the condensed water. If the acidic condensed water enters the burner or fan, it will easily corrode the components of the burner or fan.Measures must be taken to prevent condensation from entering the burner or fan.Add heat preservation for recirculating smoke pipe, reserve condensate discharge outlet, and preheat for fresh air.
Condensate water discharge device shall be set at the lowest point of each section of the circulation flue. If there is a mixing bellows, condensate water discharge device shall be set on the mixing bellows. If necessary, condensate water discharge device may also be set on the fan.The condensate water discharge device is recommended to be made into a water seal type, the highest point of the water seal is lower than the lowest point of the flue gas pipeline, to facilitate the timely discharge of condensate water.